A bathroom can be perfectly tanked and still be a bad bathroom. These are the specification decisions that cause daily irritation and cannot be undone cheaply.
Waterproofing gets the attention because it causes visible failures, and a properly tanked wet room is a genuine achievement. What gets less attention is everything else: where the drain sits, how the screen meets the floor, whether the niche is in the right wall, how the room ventilates, and whether the vanity has a serviceable connection behind it. Those decisions are made once, usually quickly, and lived with for years.
Why these keep happening
Bathrooms are specified late, in small spaces, by people looking at a plan rather than standing in a mock-up. The plan hides the three dimensions that matter most: the height of fittings relative to a person using them, the fall of the floor relative to how the water actually drains, and the depth of the wall relative to what has to be concealed inside it. Because each individual decision looks minor, none of them attracts a review, and the accumulated result is a room that works but irritates. The errors below are all cheap to prevent at drawing stage and expensive to correct after the tiling is complete.
1. Positioning the drain for plumbing convenience rather than for the floor layout
A drain position dictates the fall pattern, and the fall pattern dictates the tile layout. A central point drain in a square shower needs the floor to fall from four directions, which with large tiles produces either visible distortion or a mass of small cuts. A linear drain along one wall lets the floor fall in a single plane and large tiles work. Plumbers usually locate the drain where the connection is easiest, which is a reasonable instinct that produces an awkward floor.
- Avoid it by: Decide the drain type and position from the tile layout and fall geometry, then ask the plumber to make that position work.
- Proof it is closed: A wet-room setting-out drawing exists showing drain, falls and tile layout, accepted before pipework is fixed.
What it costs you: A shower floor with unexpected cuts, visible ponding or a surface that feels uneven underfoot, correctable only by removing the tiling.
2. Leaving fitting heights to be set on site
Shower control height, shower head height, basin rim height, mirror centre, towel rail position, niche height and the height of a wall-hung pan are all decided by whoever is holding the drill if they are not drawn. Standard heights suit an average user, and households are not average. Getting these wrong produces daily friction: a shower control you reach through the spray, a mirror that cuts off the top of your head, a towel rail you cannot use with the door open.
- Avoid it by: Draw a wall elevation for every bathroom wall with every fitting height dimensioned, and check them against the actual users.
- Proof it is closed: Dimensioned elevations are issued and marked out on the wall in tape before first fix is completed.
What it costs you: Fittings at the wrong height behind finished tiling, where moving one means cutting into the wall and matching the tile.
3. Forgetting that a wall has to be deep enough for what is hidden in it
Concealed cisterns, wall-hung pan frames, recessed shower valves, niches and recessed cabinets all need depth, and that depth comes out of the room. A specification that assumes a standard partition will not accommodate a concealed frame, which is discovered during first fix when the only options are to lose floor area, to project the wall into the room, or to abandon the fitting. In an existing building with a structural wall behind, there may be no option at all.
- Avoid it by: Fix the sanitaryware selection before the partition layout and draw a section through every wall that conceals something.
- Proof it is closed: Each concealed item appears on a wall section with its required depth, and the partition is set out to that dimension.
What it costs you: A late change of sanitaryware type, a projecting bulkhead that was never designed, or a room measurably smaller than drawn.
4. Treating ventilation as an afterthought
A bathroom without effective extraction holds humidity, which attacks joinery, promotes mould at junctions and makes a well-finished room smell wrong. Internal bathrooms with no window depend entirely on mechanical extraction, and an extract fan that is undersized, poorly ducted, discharging into a ceiling void or wired to a switch nobody uses achieves very little. The requirement is a ventilation strategy with a duct route and a discharge point, not a fan on a schedule.
- Avoid it by: Specify the extraction rate, the duct route, the discharge location and the control method, and confirm it against the requirements applying to the building.
- Proof it is closed: The ventilation is commissioned and the measured performance recorded before the ceiling is closed.
What it costs you: Persistent humidity, damaged vanity joinery, mould at sealant lines and a problem that recurs after every cleaning.
5. Specifying a floor finish that is dangerous when wet
Slip resistance is a measurable property that changes when a surface is wet and changes again when it is soapy. Polished stone and large smooth tiles chosen for appearance can be genuinely hazardous in a shower area, and the risk is highest for the youngest and oldest members of a household. The error is usually made by selecting one material for the whole bathroom from a showroom display where it is dry and horizontal.
- Avoid it by: Specify slip resistance explicitly for wet areas and ask the supplier for the tested values rather than a general assurance.
- Proof it is closed: The submittal records the slip resistance data for every wet-area floor finish and the designer has accepted it against the exposure.
What it costs you: A real safety risk, and a remedial option limited to applied treatments that change the appearance of the floor.
6. Making the vanity and the pipework unserviceable
A beautiful vanity with no access to the trap, the isolating valves or the waste connection turns a ten minute repair into a joinery job. The same applies to concealed cisterns without an access plate, and to wall-hung units fixed over a tiled surface with no provision to remove them. Serviceability is designed in, and it costs almost nothing at drawing stage.
- Avoid it by: Draw an access route to every valve, trap and cistern, and specify removable panels rather than sealed boxes.
- Proof it is closed: Each wet area has a recorded access route to its isolating valves, demonstrated before handover.
What it costs you: Damaged joinery and tiling during routine repairs, and leaks that run for longer because nobody could reach the isolator.
7. Ignoring the shower screen and door geometry
Screens and doors interact with falls, thresholds, tile layout and drainage in ways a plan does not reveal. A screen set on a sloping floor needs its seal detailed; a hinged door that opens inwards collides with a fitting; a frameless panel needs structural fixing into a substrate that may be tile over board. Water escaping at the screen junction is one of the most common complaints in a correctly waterproofed bathroom.
- Avoid it by: Detail the screen junction with the floor and the wall before tiling, and check every door swing against the installed fittings.
- Proof it is closed: The screen detail is drawn and the fabricator surveys the completed tiling before manufacture.
What it costs you: Water on the bathroom floor after every use, and a remedy that often means refabricating or repositioning the screen.
A short check before you sign
- Confirm a wet-room setting-out drawing exists for each bathroom showing drain, fall direction and tile layout.
- Check that every bathroom has dimensioned wall elevations with each fitting height stated.
- Verify that every concealed item has a wall section proving the partition depth available.
- Confirm the ventilation rate, duct route and discharge point are specified and will be commissioned.
- Check that slip resistance data has been submitted and accepted for each wet-area floor finish.
- Walk each bathroom and trace a physical access route to every isolating valve, trap and cistern.
If it has already happened
If the tiling is complete and a fitting is in the wrong place, weigh the cost of correction against living with it honestly, because partial tile removal rarely leaves an invisible repair and a second batch of tiles is unlikely to match. For drainage and fall problems, get a competent assessment of whether water is actually leaving the room before committing to any cosmetic fix, since standing water against a junction will eventually find a weakness regardless of how good the membrane is. Ventilation problems are usually the cheapest to correct after the fact, because a duct can often be rerouted through a ceiling void. Requirements for ventilation, drainage and safety in wet areas are revised periodically, so confirm the current position with the relevant authority before specifying a remedy, and where a defect raises a question of liability between trades, take it to a licensed legal adviser rather than settling it informally.
Domira designs and delivers interiors as part of the building, not after it: the finishing schedule, the joinery and the services coordination that decide whether a space looks built or assembled. Share the space and Domira will tell you what it would specify and what it would leave out.
Frequently Asked Questions
Should a shower have a linear drain or a central drain?
A linear drain against one wall lets the floor fall in a single plane, which suits large-format tiles and gives a flatter, more comfortable surface. A central point drain needs falls from several directions, which with large tiles means either distortion or many cuts. Choose the drain from the tile layout and the fall geometry, then ask the plumbing to accommodate it rather than the reverse.
How do I stop water escaping from the shower onto the bathroom floor
Almost always by correcting the geometry rather than adding sealant. Check that the floor actually falls towards the drain across its whole area, that the screen junction with the floor and wall is detailed rather than improvised, and that the shower head is not directed at the opening. A screen fabricated after the tiling is complete, from a survey of the finished surface, fits far better than one ordered from a drawing.
Does an internal bathroom with no window need mechanical extraction?
It needs a proper ventilation strategy, which in an internal room means mechanical extraction with a sized fan, a duct route to an external discharge and a control arrangement that actually runs. Discharging into a ceiling void simply moves the humidity somewhere less visible. Confirm the applicable requirement for your building with the relevant authority and have the installation commissioned and recorded.